PART NUMBER: 2111.7005.63

TV analyzer Features * Measurement functions for analog and digital TV signals * Full-fledged spectrum analyzer * Combined video/ASI output * Compact and robust housing * Up to four hours operating time on battery power * Wide selection of accessories for diverse measurement tasks * Preselector option with 75? RF input General The TV Analyzer R&S FSH3-TV combines the functions and features of a complete spectrum analyzer with those of a TV test receiver in a single measurement instrument. It can be taken wherever needed and is ideal for technicians who perform measurements on site – for example, during new installations or maintenance and repair work on components of TV cable networks and transmitters. Robust and portable The instrument's compact housing is designed for portable use. Its robust edge protection and RF connector covers safeguard the R&S FSH3-TV against mechanical and weather-related conditions. The R&S FSH3-TV weighs only 2.8 kg. It has a sturdy carrying handle that also makes reading the display easy when the instrument is placed on a flat surface. In addition, an integrated stand allows the R&S FSH3-TV to be positioned to the optimum angle for reading results. The powerful, built-in NiMH battery can power the instrument for up to four hours, thus providing reliable operation even at remote locations. Convenient operation The R&S FSH3-TV is operated by means of convenient menus and softkeys. Frequently used functions can be selected directly. In addition, a rotary knob allows quick and easy variation of entry values and the selection of items from menus. Measured values and menus are shown on a backlit color liquid crystal display. The display remains legible even under difficult lighting conditions (daylight). Well-equipped The TV Analyzer R&S FSH3-TV comes equipped with a TV board, a preamplifier and a tracking generator. The TV board permits measurements of analog TV signals and their demodulation. The demodulated video signal, which is made available at an output that can be used either as a CCVS (analog TV) or as a TS-ASI (digital TV) output, can be routed to an external monitor or an MPEG decoder. The supplied headphones can be used to listen to the sound of the analog TV signal. Made for TV The TV Analyzer R&S FSH3-TV offers the same scope of functions as any spectrum analyzer from the R&S FSH family of Rohde & Schwarz instruments. However, additional settings and options have been added that are specially designed for measurements needed by TV cable operators and transmitter network operators. The main expansion is the TV board integrated in the base unit. This board provides additional capabilities for analyzing and demodulating analog and digital TV signals. The following table provides a summary of the available TV standards. The R&S FSH3-TV comes equipped with a female N connector (50 ?) for the RF input. To ensure that the correct characteristic impedance is achieved when the R&S FSH3-TV is connected to cable network components or, for example, to TV antenna systems with 75 ? impedance, the R&S RAZ and R&S FSH-Z38 50 ?/75 ? matching pads are offered as options.
 
ModelSKUDescription
FSHTV-K12111.7140.02Remote control for R&S FSH3-TV
FSHTV-K212111.7211.02DVB-C/J.83/A,B,C (QAM) firmware for R&S FSH3-TV
FSHTV-Z602111.7105.02Pre-selector for R&S FSH3-TV
FSHTV-Z612111.7111.02Spare F adapter (female/female) for R&S FSH3-TV
FSH-Z211304.5593.0012V car adapter. Connector for cigarette lighter (for FSH3/6/18)
FSH-Z251145.5896.02Soft carrying bag for FSH3/6/18
FSH-B11145.5750.02Option: Distance To Fault measurement for FSH3/6 ( model .13/.23/.26 only), including 1 m cable (FSH-Z2 or
FSH-K31157.3429.02Receiver mode for FSH3/6
FSHTV-K222111.7228.02ATSC/8VSB firmware for R&S FSH3-TV
FSH-Z11155.4505.02Average power sensor for FSHx 10 MHz - 8 GHz, 200 pW - 200 mW
FSH-Z141120.6001.02Directional power sensor 25 MHz - 1 GHz, 30 mW - 120(300)W N-female for FSHx
FSH-Z181165.1909.02Average power sensor 10 MHz - 18 GHz, 200 pW - 200 mW for FSHx
FSH-Z21145.5767.02VSWR bridge and power divider for FSH3/6 (model .13/.23/26 only) 10 MHz - 3 GHz, incl. FSH-Z29
FSH-Z201145.5867.02Spare N-cable to option DTF FSH-B1, 1 m, male/female N-connector up to 6 GHz
FSH-Z221145.5880.02Serial/parallel converter for printers with parallel interface for FSH3/6/18
FSH-Z261300.7627.02Hard case for FSH3/6/18
FSH-Z291300.7504.02Spare load/open/short calibration standard for FSH3/6 N-connector
FSH-Z301145.5773.02Spare open/short standard for FSH-Z2, for calibration of VSWR measurement
FSH-Z311145.5780.02Spare 50 Ohm load standard for FSH-Z2, for calibration of VSWR and DTF measurement
FSH-Z321145.5796.02Spare battery pack for FSH
FSH-Z331145.5809.02Spare power supply for FSH3/6/18 including mains plug for EU, GB and US
FSH-Z341145.5815.02Optical RS232 interface cable 1.5 m for FSH3/6/18 (spare)
FSH-Z361145.5838.02Spare headphones for FSH3/6/18, additional haedphones for
FSH-Z371300.7733.02Optical USB interface cable, 1.5 m for FSH3/6/18 (spare)
FSH-Z381300.7740.0275 ohm matching pad N to BNC (female)
FSH-Z441165.2305.02Directional power sensor 200 MHz - 4 GHz, 30mW - 120(300) W for FSHx
RAZ0358.5714.02Matching pad 50/75 Ohm, 0 - 2700 MHz, matching at one end, N-connectors
FSH3-TV2111.7005K63TV analyzer
FSH3-TV-C32111.7005.63.C3Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s).
FSH3-TV-C52111.7005.63.C5Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s).
FSH3-TV-R32111.7005.63.R3Three years of depot repair coverage, including recalibration and test data if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty.
FSH3-TV-R52111.7005.63.R5Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty
FSH41309.6000.04Handheld spectrum analyzer 9kHz to 3.6GHz, with preamplifier
FSH-K401304.5606.02Remote control via LAN or USB für FSH4/8 (software license)
FSH-K411304.5612.02Distance To Fault measurement for FSH4/8 (for model .24 and .28 only,
FSH-K421304.5629.02Vector reflection and transmission measurement (for FSH4/8 model .24 and .28 only)
FSH-Z281300.7810.03Load/short/open calibration standard for FSH4/8; DC to 8GHz, N connector
FSH-Z291300.7510.03Load/short/open calibration standard for FSH4/8; DC to 4GHz, N connector
FSH-Z3201309.6600.00RF cable (1m), DC to 8GHz, connectors N(m)/N(f), for DTF measurements
FSH-Z3211309.6617.00RF cable (3m), DC to 8GHz, connectors N(m)/N(f), for DTF measurements
HA-Z2011309.6100.00Spare power supply including main plug (for EU, GB and USA;
HA-Z2021309.6117.0012V car adapter. Connector for cigarette lighter (for PR100, FSH4/8 and ETH)
HA-Z2031309.6123.00Battery charger for lithium-ion battery pack 4.5AH/6.75AH (for PR100, FSH4/8 and ETH)
HA-Z2061309.6146.00LI-ION Battery pack 6.75Ah (for PR100, FSH4/8 and ETH)
HA-Z2101309.6152.00Spare Ethernet cabel 2m; (for PR100, FSH4/8 and ETH)
HA-Z2111309.6169.00Spare USB cable 1.8m, standard/mini-USB connectors (for PR100, FSH4/8 and ETH)
HA-Z2201309.6175.00Soft carrying bag (for PR100, FSH4/8 and ETH)
HA-Z2311309.6217.00SD memory card 1GB, (for PR100, FSH4/8 and ETH)

See our equipment specials page for outstanding values this month. Visit our ebay store for other sale items. We buy surplus test equipment.

  • Model: FSH3-TV
  • Manufactured by: Rohde & Schwarz

Fill out the form below for more information about Rohde & Schwarz FSH3-TV.

* Required information

Your Details:
 *
 *
 *


*
 *